MAINTENANCE
Routine Inspection: Not required except for periodic inspection of the cable and connector to
ensure that these are neither damaged nor softened by incompatible liquid.
TABLE 1
ELECTRICAL CONNECTIONS
mV 4-20mA 0-10V
Type
Number
Connector
In+ Out+ Out- In- Earth In+ In- Earth In+ Com Out+ Earth
524-BP Cable R Y B W Drain
524-11 Cable R BL Drain
524-2C Cable R W Y Drain
Output Supply Voltage
BP 0 to 100mV 10V d.c.
11 4 to 20mA 8 – 28V d.c.
2C 0 to 10V 13 to 28V d.c.