Setra-system Model 3200 Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
5
0.75 (19)
1.50 (38)
4
3
1
2
Deutsch DT04-4P
(Code 8)
Pin Voltage Current
# Mode Mode
1
V
out1
No
(pressure) Connect
2
V
Supply
V
Supply
3
V
out2
No
(temp)
Connect
4 Ground Return
Pin Voltage Current
# Mode Mode
1
V
Supply
V
Supply
2
V
out1 No
(pressure) Connect
3 Ground Return
4
V
out2 No
(temp) Connect
DIN 9.4mm* (Code B)
M12 x 1P (Code E)
Packard Metri Pack
(Code 9)
Amp Superseal 1.5
(Code 6)
*mating connector not supplied
Electrical Connections, Diagram A
(see page 7 for mating connectors)
Rated psi 150 230 300 500 1000 1500 2300 3600 6000 10000 15000 25000
Range bar 10 16 20 35 70 100 160 250 400 700 1000 1600
Max. Over
Pressure (<)
Min. Burst (>) X40 X20 X10 >4000 bar
Pin Voltage Current
# Mode Mode
1 Ground Return
2
V
Supply
V
Supply
3
V
out2 No
(temp) Connect
4
V
out1 No
(pressure) Connect
1.53 (39)
0.75 (19)
B
C
A
1.02 (26)
1.46 (37)
1 2 3
0.28 (7)
0.75 (19)
0.76 (19)
2
3
1
4
0.38 (10)
0.72 (18)
0.75 (19)
3
4
1
2
2.17 (55)
1.42 (36)
0.75 (19)
Integral Cable/Flying Leads
(Code F)
in. (mm)
Voltage Current
Color Mode Mode
R
V
Supply
V
Supply
B Ground Return
G
V
out1 No Connect
(pressure)
W
V
out2 No Connect
(temp)
Pin Voltage Current
# Mode Mode
1
V
out1 No
(pressure) Connect
2 Ground Return
3
V
Supply
V
Supply
Miswire Protection Option
• Full miswire protection between all
signal and power lines (any combination)
• Full short-circuit protection for Vout1
to 0V or Vout1 connected to supply,
indenitely.
Temperature outputs not available.
• Ratiometric output not available.
• Supply Voltage must be 4V above
the maximum Vout1 output. This also
accounts for worse-case customer output
leads.
Pin Voltage Current
# Mode Mode
A Ground Return
B
v
Supply
v
Supply
C
v
out1 No
(pressure) Connect
Vista de pagina 4